Heidenhain TNC 320 (340 55x-03) Touch Probe Cycles User Manual Page 83

  • Download
  • Add to my manuals
  • Print
  • Page
    / 165
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 82
HEIDENHAIN TNC 320 83
3.2 Presetting automatically
8 Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.
8 Setup clearance Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to column SET_UP.
8 Clearance height Q260 (absolute): Coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
8 Traversing to clearance height Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
8 Datum number in table Q305: Enter the datum
number in the table in which the TNC is to save the
coordinates of the pocket center. If you enter
Q305=0, the TNC automatically sets the display so
that the new datum is on the stud center.