Heidenhain TNC 320 (340 55x-03) Touch Probe Cycles User Manual Page 84

  • Download
  • Add to my manuals
  • Print
  • Page
    / 165
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 83
84
3.2 Presetting automatically
8 New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the stud center. Basic setting = 0
8 New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC should
set the stud center. Basic setting = 0
8 Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use. Is entered by the TNC when old
programs are read in (see “Saving the calculated
datum” on page 64).
0: Write determined datum in the active datum table.
The reference system is the active workpiece
coordinate system.
1: Write determined datum in the preset table. The
reference system is the machine coordinate system
(REF system).
8 Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set datum in the touch probe axis
1: Set datum in the touch probe axis
8 Probe TS axis: Coord. 1. st axis Q382 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 = 1.
8 Probe TS axis: Coord. 2. nd axis Q383 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 = 1.
8 Probe TS axis: Coord. 3. rd axis Q384 (absolute):
Coordinate of the probe point in the reference axis of
the working plane at which point the datum is to be
set in the touch probe axis. Only effective if Q381 = 1.
8 New datum for touch probe axis Q333 (absolute):
Coordinate in the touch probe axis at which the TNC
should set the datum. Basic setting = 0
8 No. of measuring points (4/3) Q423: Specify
whether the TNC should measure the stud with 4 or
3 probing points:
4: Use 4 measuring points (standard setting)
3: Use 3 measuring points (standard setting)
Example: NC blocks
5 TCH PROBE 413 DATUM OUTSIDE CIRCLE
Q321=+50 ;CENTER 1ST AXIS
Q322=+50 ;CENTER 2ND AXIS
Q262=75 ;NOMINAL DIAMETER
Q325=+0 ;STARTING ANGLE
Q247=+60 ;STEPPING ANGLE
Q261=-5 ;MEASURING HEIGHT
Q320=0 ;SET-UP CLEARANCE
Q260=+20 ;CLEARANCE HEIGHT
Q301=0 ;MOVE TO CLEARANCE
Q305=15 ;NO. IN TABLE
Q331=+0 ;DATUM
Q332=+0 ;DATUM
Q303=+1 ;MEAS. VALUE TRANSFER
Q381=1 ;PROBE IN TS AXIS
Q382=+85 ;1ST CO. FOR TS AXIS
Q383=+50 ;2ND CO. FOR TS AXIS
Q384=+0 ;2RD CO. FOR TS AXIS
Q333=+0 ;DATUM
Q423=4 ;NO. OF MEAS. POINTS