3.2 Presetting automatically
Saving the calculated datum
In all cycles for datum setting you can use the input parameters Q303
and Q305 to define how the TNC is to save the calculated datum:
Q305 = 0, Q303 = any value
The TNC sets the calculated datum in the display. The new datum is
active immediately.
Q305 not equal to 0, Q303 = -1
Q305 not equal to 0, Q303 = 0
The TNC writes the calculated reference point in the active datum
table. The reference system is the active workpiece coordinate
system. The value of parameter Q305 determines the datum
number. Activate datum with Cycle 7 in the part program.
Q305 not equal to 0, Q303 = 1
The TNC writes the calculated reference point in the preset table.
The reference system is the machine coordinate system (REF
coordinates). The value of parameter Q305 determines the preset
number. Activate preset with Cycle 247 in the part program.
Measurement results in Q parameters
The TNC saves the measurement results of the respective touch
probe cycle in the globally effective Q parameters Q150 to Q160. You
can use these parameters in your program. Note the table of result
parameters that are listed with every cycle description.
This combination can only occur if you
read in programs containing Cycles 410 to 418 created
on a TNC 4xx
read in programs containing Cycles 410 to 418 created
with an older software version on an iTNC 530
did not yourself define the measured-value transfer with
parameter Q303 in the cycle definition
In these cases the TNC outputs an error message, since
the complete handling of REF-referenced datum tables
has changed. You must define a measured-value transfer
yourself with parameter Q303.