Heidenhain TNC 320 (340 55x-03) Touch Probe Cycles User Manual Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 165
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
HEIDENHAIN TNC 320 57
3.1 Measuring Workpiece Misalignment
Compensating workpiece misalignment by
rotating the C axis (touch probe cycle 405,
DIN/ISO: G405)
With touch probe cycle 405, you can measure
the angular offset between the positive Y axis of the active
coordinate system and the center of a hole, or
the angular offset between the nominal position and the actual
position of a hole center.
The TNC compensates the determined angular offset by rotating the
C axis. The workpiece can be clamped in any position on the rotary
table, but the Y coordinate of the hole must be positive. If you
measure the angular misalignment of the hole with touch probe axis Y
(horizontal position of the hole), it may be necessary to execute the
cycle more than once because the measuring strategy causes an
inaccuracy of approx. 1% of the misalignment.
1 The TNC positions the touch probe at rapid traverse (value from
FMAX column) following the positioning logic (see “Running touch
probe cycles” on page 21) to the starting point 1. The TNC
calculates the probe starting points from the data in the cycle and
the safety clearance from the SET_UP column of the touch probe
table
2 Then the touch probe moves to the entered measuring height and
runs the first probing process at the probing feed rate (column F).
The TNC derives the probing direction automatically from the
programmed starting angle.
3 Then the touch probe moves in a circular arc either at measuring
height or at clearance height to the next starting point 2 and probes
the second touch point.
4 The TNC positions the probe to starting point 3 and then to starting
point 4 to probe the third and fourth touch points and positions the
touch probe on the hole centers measured.
5 Finally the TNC returns the touch probe to the clearance height and
aligns the workpiece by rotating the table. The TNC rotates the
rotary table so that the hole center after compensation lies in the
direction of the positive Y axis, or on the nominal position of the
hole center — both with a vertical and horizontal touch probe axis.
The measured angular misalignment is also available in parameter
Q150.
X
Y
1
2
4
3
X
Y
Before programming, note the following
To prevent a collision between the touch probe and the
workpiece, enter a low estimate for the nominal diameter
of the pocket (or hole).
If the dimensions of the pocket and the safety clearance
do not permit pre-positioning in the proximity of the touch
points, the TNC always starts probing from the center of
the pocket. In this case the touch probe does not return to
the clearance height between the four measuring points.
Before a cycle definition you must have programmed a
tool call to define the touch probe axis.
Page view 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 164 165

Comments to this Manuals

No comments