3.1 Measuring Workpiece Misalignment
Characteristics common to all touch probe
cycles for measuring workpiece misalignment
For Cycles 400, 401 and 402 you can define through parameter Q307
Default setting for basic rotation whether the measurement
result is to be corrected by a known angle α (see figure at right). This
enables you to measure the basic rotation against any straight line 1
of the workpiece and to establish the reference to the actual 0°
direction 2.