3.2 Presetting automatically
8 Center in 1st axis Q321 (absolute value): Center of
the stud in the reference axis of the working plane.
8 Center in 2nd axis Q322 (absolute value): Center of
the stud in the minor axis of the working plane. If you
program Q322 = 0, the TNC aligns the hole center to
the positive Y axis. If you program Q322 not equal to
0, then the TNC aligns the hole center to the nominal
position.
8 Nominal diameter Q262: Approximate diameter of the
stud. Enter a value that is more likely to be too large
than too small.
8 Starting angle Q325 (absolute): Angle between the
reference axis of the working plane and the first touch
point.
8 Stepping angle Q247 (incremental): Angle between
two measuring points. The algebraic sign of the
stepping angle determines the direction of rotation
(- = clockwise) in which the touch probe moves to the
next measuring point. If you wish to probe a circular
arc instead of a complete circle, then program the
stepping angle to be less than 90°.
X
Y
Q322
Q321
Q262
Q325
Q247
X
Z
Q261
Q260
MP6140
+
Q320
The smaller the angle, the less accurately the TNC can
calculate the datum. Minimum input value: 5°.