HEIDENHAIN TNC 320 27
2.1 Introduction
Writing the measured values from touch probe
cycles in datum tables
With the ENTER IN DATUM TABLE soft key, the TNC can write the
values measured after any touch probe cycle into a datum table active
for machine operation:
8 Select any probe function
8 Enter the desired coordinates of the datum in the appropriate input
boxes (depends on the touch probe cycle being run).
8 Enter the datum number in the Number in table= input box.
8 Enter the name of the datum table (complete path) in the Datum
table input box.
8 Press the ENTER IN DATUM TABLE soft key. The TNC saves the
datum in the indicated datum table under the entered number.
Use this function if you want to save measured values in
the workpiece coordinate system. If you want to save
measured values in the fixed machine coordinate system
(REF coordinates), press the ENTER IN PRESET TABLE
soft key (see “Writing the measured values from touch
probe cycles in the preset table” on page 28).