3.3 Automatic Workpiece Measurement
8 Measuring axis Q272: Axis in the working plane in
which the measurement is to be made:
1:Reference axis = measuring axis
2:Minor axis = measuring axis
8 Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (= touch
point) in the touch probe axis in which the
measurement is to be made.
8 Setup clearance Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to column SET_UP.
8 Clearance height Q260 (absolute): Coordinate in the
touch probe axis at which no collision between tool
and workpiece (fixtures) can occur.
8 Nominal length Q311: Nominal value of the length to
be measured.
8 Maximum dimension Q288: Maximum permissible
length.
8 Minimum dimension Q289: Minimum permissible
length.
8 Measuring log Q281: Definition of whether the TNC is
to create a measuring log:
0: No measuring log
1: Generate measuring log: The TNC saves the log
file TCHPR426.TXT by default in the directory TNC:\
2: Interrupt the program run and display the
measuring log on the screen. Resume program run
with NC Start.
8 PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance limits
the TNC is to interrupt the program run and output an
error message:
0: Do not interrupt program run, no error message
1: Interrupt program run, output an error message
8 Tool number for monitoring Q330: Definition of
whether the TNC is to monitor the tool (see “Tool
monitoring” on page 108)
0: Monitoring not active
>0: Tool number in the tool table TOOL.T
Example: NC blocks
5 TCH PROBE 426 MEASURE RIDGE WIDTH
Q263=+50 ;1ST POINT 1ST AXIS
Q264=+25 ;1ST POINT 2ND AXIS
Q265=+50 ;2ND POINT 1ST AXIS
Q266=+85 ;2ND POINT 2ND AXIS
Q272=2 ;MEASURING AXIS
Q261=-5 ;MEASURING HEIGHT
Q320=0 ;SET-UP CLEARANCE
Q260=+20 ;CLEARANCE HEIGHT
Q311=45 ;NOMINAL LENGTH
Q288=45 ;MAX. LIMIT
Q289=44.95 ;MIN. LIMIT
Q281=1 ;MEASURING LOG
Q309=0 ;PGM STOP IF ERROR
Q330=0 ;TOOL NUMBER