HEIDENHAIN iTNC 530 439
11.6 Optional block skip
11.6 Optional block skip
Function
In a test run or program run, the TNC can skip over blocks that begin
with a slash /:
U
UU
U To run or test the program without the blocks
preceded by a slash, set the soft key to ON.
U
UU
U To run or test the program with the blocks preceded
by a slash, set the soft key to OFF.
This function does not work for TOOL DEF blocks.
After a power interruption the control returns to the most
recently selected setting.